The Honeywell 5816 is a versatile wireless door/window transmitter designed for security systems, offering two unique zones for flexible installation and monitoring solutions.

Overview of the Honeywell 5816 Door/Window Transmitter

The Honeywell 5816 is a wireless door/window transmitter designed for security systems, offering two unique zones for monitoring. It features a built-in reed switch for use with a magnet and a wired closed circuit contact loop. Compact and versatile, it operates on a 3V lithium battery, ensuring reliable performance. With a range of up to 200 feet, it supports both indoor and outdoor applications. Its tamper switch enhances security, and it is UL-compliant for supervised RF installations, making it a robust solution for home and commercial security needs.

  • Two-zone functionality for flexible monitoring.
  • Long-range wireless communication up to 200 feet.
  • Built-in reed switch and wired contact loop options.
  • Compact design with easy installation and maintenance.

Key Features and Benefits of the Honeywell 5816

The Honeywell 5816 offers dual-zone functionality, combining a wired closed circuit contact loop with a built-in reed switch for magnetic activation. Its wireless design ensures seamless integration with security panels, while the 200-foot range enhances reliability. The tamper-resistant cover adds an extra layer of security. Battery life is extended with its efficient 3V lithium power system. Suitable for various environments, it supports UL-compliant installations and is easily programmable, making it a versatile and dependable choice for security systems.

  • Dual-zone monitoring for comprehensive security coverage.
  • Long-range wireless communication for reliable performance.
  • Tamper-resistant design for enhanced security.
  • Efficient battery life with low-maintenance requirements.

Installation and Setup

Mounting involves removing the cover, disengaging the plate, and securing it with screws. Wired contacts are fed through concealed holes, and Go/No Go tests ensure signal strength.

Step-by-Step Installation Guide for the Honeywell 5816

Remove the cover using a screwdriver at the pry-off slot.
Disengage the mounting plate by pressing the locking tab.
Feed wires through concealed holes for hidden wiring.
Mount the plate with screws, ensuring correct orientation.
Attach the case back, locking it in place.
Install the magnet adjacent to alignment marks.
Connect the contact loop if used.
Insert the battery, ensuring polarity is correct.
Conduct Go/No Go tests for signal verification.
Reorient or relocate if signal strength is inadequate.

Mounting and Wiring Instructions for the Honeywell 5816

Mount the unit using the provided plate, ensuring correct orientation. Feed wires through concealed holes for hidden installation or use surface wiring. Attach the case back securely, locking it in place. Install the magnet adjacent to alignment marks for proper reed switch function. Connect the wired loop to terminals if used, ensuring correct polarity. Insert the battery carefully to avoid bending the antenna. Follow all safety guidelines for proper installation and functionality.

Zones and Configuration

Zones and Configuration

The Honeywell 5816 features two unique zones: one for a wired closed circuit loop and another for a built-in reed switch with a magnet.

Understanding the Two Unique Zones of the Honeywell 5816

The Honeywell 5816 features two distinct zones, providing flexibility for security setups. Zone 1 is dedicated to a wired closed-circuit contact loop, ideal for integrating external sensors or devices. Zone 2 utilizes the built-in reed switch, which works in conjunction with a magnet for detecting door or window openings. Both zones can be used independently or together, offering comprehensive monitoring solutions for various security needs. This dual-zone functionality enhances the device’s versatility in home or commercial security systems.

Configuring the Wired Closed Circuit Contact Loop

The Honeywell 5816’s wired closed circuit contact loop is configured using Zone 1, enabling integration with external sensors or devices. This loop requires closed-circuit devices to function properly, with a nominal response time of 100ms. To set up, connect the wires to the loop terminals, ensuring correct polarity. If the loop isn’t used, no connections are needed across its terminals. This feature allows for flexible security configurations, adapting to various monitoring requirements while maintaining reliable performance.

Reed Switch and Magnet Setup

The Honeywell 5816 features a built-in reed switch that works with a magnet for door/window monitoring. The magnet must align with the transmitter’s alignment marks for proper operation.

Using the Built-In Reed Switch with a Magnet

The Honeywell 5816 incorporates a built-in reed switch designed to work with a magnet for reliable door or window monitoring. When the magnet is placed near the reed switch, it triggers the sensor, indicating the door or window is closed; Proper alignment is crucial; the magnet should be positioned adjacent to the transmitter’s alignment marks. This setup ensures accurate detection of door or window status, providing a secure and efficient monitoring solution for home or business security systems.

Aligning the Magnet with the Honeywell 5816

Proper alignment of the magnet with the Honeywell 5816 is essential for reliable operation. The magnet should be placed adjacent to the reed switch, aligning with the marks on the transmitter and mounting plate. Ensure the magnet is positioned correctly to trigger the reed switch when the door or window is closed. Use a No. 5799 magnet or equivalent for optimal performance. Misalignment can cause false readings, so precise placement is crucial for accurate detection and system reliability.

Battery Installation and Maintenance

The Honeywell 5816 uses a 3V lithium battery (Panasonic CR123A or equivalent). Replace the battery with the transmitter cover off, ensuring proper polarity to avoid damage.

Installing the Battery in the Honeywell 5816

To install the battery, remove the transmitter cover by prying it open with a small screwdriver. Insert the 3V lithium battery (e.g., Panasonic CR123A) into the holder, ensuring correct polarity. Avoid bending the antenna during this process. Once installed, replace the cover securely. Always use the recommended battery type to maintain optimal performance and avoid damage. Dispose of used batteries responsibly to prevent environmental harm.

Replacing the Battery in the Honeywell 5816

To replace the battery, first remove the transmitter cover by inserting a screwdriver into the pry-off slot. Carefully pull the cover away and locate the battery holder. Remove the old battery and dispose of it responsibly. Insert a new 3V lithium battery (e.g., Panasonic CR123A or Duracell DL123A) into the holder, ensuring correct polarity. Avoid bending the antenna during this process. Replace the cover securely to maintain proper function. Never recharge or disassemble the battery to prevent fire or explosion risks.

Signal Strength and Testing

Ensure reliable performance by conducting Go/No Go tests to verify signal strength. Reorient or relocate the transmitter if necessary for optimal communication with the control panel.

Conducting Go/No Go Tests for Signal Strength

Perform Go/No Go tests to ensure the Honeywell 5816 transmitter maintains reliable communication with the control panel. These tests verify signal strength and range before permanent installation. Temporarily mount the transmitter, remove the cover, and ensure the battery is installed. Use the control panel to check signal quality. If the signal is weak, reorient or relocate the transmitter for optimal performance. Conduct these tests annually to maintain system reliability and ensure uninterrupted monitoring of secured areas.

Reorienting or Relocating the Transmitter for Optimal Signal

For optimal signal strength, reorient or relocate the Honeywell 5816 transmitter as needed. Temporarily place the unit and conduct Go/No Go tests to assess communication quality. If signal strength is inadequate, adjust the transmitter’s position, ensuring it is not obstructed by metal objects or walls. Relocate it higher or closer to the control panel if necessary. Ensure the antenna is not bent or damaged. Annual testing is recommended to maintain reliable performance and adapt to any environmental changes affecting signal quality.

Programming the Honeywell 5816

Enroll the transmitter’s serial number in the control panel before use. For UL installations, treat the 5816 as a supervised RF type to ensure compliance and functionality.

Enrolling the Transmitter Serial Number in the Control Panel

The Honeywell 5816 transmitter requires enrolling its unique serial number in the control panel before operation. This step ensures proper communication and functionality within the security system. Refer to the control panel’s installation instructions for specific enrollment procedures. For UL installations, the transmitter must be treated as a supervised RF type to meet regulatory requirements. Enrolling the serial number is essential for system recognition and ensures reliable performance in monitoring doors and windows. This process guarantees seamless integration into your home security setup;

Programming the Honeywell 5816 for UL Installations

For UL installations, the Honeywell 5816 must be programmed as a supervised RF type to meet regulatory standards. This ensures the system monitors the transmitter regularly for tamper and communication issues. The control panel’s installation instructions provide specific steps for this configuration. Proper enrollment of the serial number and zone setup are crucial for compliance and reliable performance in security systems. Always follow UL guidelines to maintain certification and ensure optimal functionality of the Honeywell 5816 transmitter.

Troubleshooting Common Issues

Common issues with the Honeywell 5816 include signal strength problems and connectivity loss. Conduct Go/No Go tests and reorient the transmitter to ensure optimal performance and reliability.

Resolving Signal Strength Problems with the Honeywell 5816

Signal strength issues with the Honeywell 5816 can often be resolved by reorienting or relocating the transmitter. Conduct Go/No Go tests to verify signal strength and ensure optimal placement. Physical obstructions or interference from other devices may weaken the signal. If issues persist, check for proper installation and alignment of the magnet and reed switch. Regular maintenance, including annual inspections, can help prevent connectivity problems and ensure reliable performance.

Fixing Connectivity Issues with the Honeywell 5816

To resolve connectivity issues with the Honeywell 5816, ensure the transmitter is properly enrolled in the control panel. Check for correct polarity when installing the battery and verify wiring connections if using a closed circuit loop. Conduct Go/No Go tests to assess signal strength and reposition the transmitter if necessary. Ensure no physical obstructions are causing interference. If issues persist, consult the manual for advanced troubleshooting steps or contact Honeywell support for further assistance.

Advanced Features and Settings

The Honeywell 5816 features advanced settings like a built-in cover tamper switch for added security and supervised RF for reliable UL installations, enhancing overall system performance and compliance.

Using the Built-In Cover Tamper Switch

The Honeywell 5816 incorporates a built-in cover tamper switch, which activates when the cover is removed, providing an additional layer of security by alerting the system to potential tampering. This feature enhances the device’s reliability in monitoring and ensures that any unauthorized access or manipulation is detected promptly. The tamper switch is integrated into the transmitter’s design, making it a seamless and effective security measure without requiring additional components or wiring.

Understanding Supervised RF Type for UL Installations

The Honeywell 5816 must be treated as a supervised RF type for UL installations, ensuring the system monitors the transmitter’s status regularly. This setup requires enrolling the transmitter’s serial number in the control panel to maintain proper supervision. Supervised RF ensures the system detects issues like signal loss or tampering, critical for compliance with UL standards. This feature enhances reliability and security in alarm systems, providing continuous monitoring and alerts for any connectivity or operational issues with the transmitter.

Outdoor and Specialized Use Cases

The Honeywell 5816 excels in outdoor environments, offering a demonstrated range of over a mile for wireless communication. Its durability and reliability make it ideal for specialized security setups.

Using the Honeywell 5816 in Outdoor Environments

The Honeywell 5816 is designed for outdoor use, with a demonstrated range of over a mile, making it ideal for large properties or remote locations. Its weather-resistant design ensures reliability in harsh conditions. For optimal performance, mount the transmitter securely and ensure proper alignment with the magnet. Regular maintenance, such as battery checks and signal testing, is crucial for consistent operation in outdoor settings. This durability and range make the 5816 a robust choice for outdoor security needs.

Long-Range Wireless Communication with the Honeywell 5816

The Honeywell 5816 excels in long-range wireless communication, offering a demonstrated outdoor range of over a mile. This makes it suitable for large properties or remote locations. Its robust signal strength ensures reliable connectivity, even in challenging environments. However, physical obstacles like walls or interference from other devices can affect performance. Proper installation and testing are crucial to maximize range. Regular signal strength tests and repositioning as needed ensure optimal performance and uninterrupted security monitoring. This feature enhances its versatility for various security applications.

Compatibility and Integration

The Honeywell 5816 seamlessly integrates with Honeywell Home Security Systems and other compatible devices, ensuring enhanced security solutions through reliable wireless communication and advanced system compatibility.

Compatibility with Honeywell Home Security Systems

The Honeywell 5816 is fully compatible with Honeywell Home Security Systems, including popular panels like Vista and Lynx. Designed as part of the ADEMCO series, it integrates seamlessly with Honeywell’s security infrastructure, ensuring reliable performance and enhanced system functionality. The transmitter’s unique serial number must be enrolled in the control panel for proper operation. Its compatibility extends to UL installations, requiring specific configurations. With a 200-foot range and robust wireless communication, the 5816 supports flexible security setups, making it a versatile choice for home and business security needs.

Integrating the Honeywell 5816 with Other Security Devices

The Honeywell 5816 can be seamlessly integrated with various security devices, enhancing overall system functionality. It works alongside door locks, smart home hubs, and video cameras, providing comprehensive security coverage. The transmitter’s compatibility with third-party systems allows for customized security solutions, while its built-in Reed switch and wired loop options offer flexibility. Advanced features like supervised RF ensure reliable communication and integration with existing systems.

Important Safety Information

The Honeywell 5816 complies with FCC and IC regulations, ensuring safe operation; Avoid unauthorized modifications to prevent voiding certification. Dispose of batteries properly to prevent environmental harm and risks of fire or explosion.

FCC and IC Compliance Statements for the Honeywell 5816

The Honeywell 5816 complies with FCC Part 15 and IC RSS 210 regulations, ensuring interference-free operation. Users must not modify the device without authorization, as this could void its certification and operational authority. The device operates under two conditions: it must not cause harmful interference and must accept all received interference, including that which may disrupt operation. Adhering to these guidelines ensures safe and reliable performance of the transmitter in various security applications.

Battery Safety Precautions for the Honeywell 5816

The Honeywell 5816 uses a 3V lithium battery, specifically a Panasonic CR123A or Duracell DL123A. To ensure safety, never recharge, disassemble, or expose the battery to temperatures above 100°C. Avoid incineration and dispose of used batteries promptly. Only replace the battery with the specified type to prevent damage. Keep batteries out of children’s reach to avoid accidents. Proper handling is crucial for maintaining device performance and safety.

Regular Maintenance and Care

Regular maintenance includes annual inspections, monthly testing, and cleaning the sensor and contacts. Ensure proper alignment and replace batteries as needed for optimal performance.

Annual Inspection and Maintenance Schedule

The Honeywell 5816 requires annual inspections to ensure optimal performance. Check the battery health and replace it if necessary, inspect wiring for damage or corrosion, and verify proper magnet alignment. Clean the sensor and contacts to prevent interference. Ensure the transmitter is securely mounted and test signal strength. Address any issues promptly to maintain reliability and extend the device’s lifespan.

Cleaning and Servicing the Honeywell 5816

Regularly clean the Honeywell 5816 to ensure proper functionality. Use a soft, dry cloth to wipe the exterior and remove dirt or debris. Gently clean the reed switch and contacts with a cotton swab to prevent interference. Avoid using harsh chemicals or liquids. Inspect the magnet alignment and battery terminals for corrosion. Replace worn or damaged parts as needed. Servicing should be performed by a qualified technician for complex issues, ensuring optimal performance and reliability over time.

Technical Specifications

The Honeywell 5816 measures 1-9/16″W x 3-1/16″H x 1-3/16″D and uses a 3V lithium battery, lasting up to five years with a 200-foot wireless range.

Physical Dimensions and Weight of the Honeywell 5816

The Honeywell 5816 measures 1-9/16 inches in width, 3-1/16 inches in height, and 1-3/16 inches in depth, translating to 40mm x 78mm x 30mm. It weighs approximately 3.2 ounces, making it lightweight for easy installation. The compact design allows for discreet placement on doors or windows without compromising functionality. Its durable construction ensures reliability, while its sleek dimensions blend seamlessly into various environments. The unit is designed for both indoor and outdoor use, with a robust build to withstand environmental conditions.

Power Requirements and Battery Life of the Honeywell 5816

The Honeywell 5816 operates on a 3V lithium battery, specifically compatible with Panasonic CR123A or Duracell DL123A models. The battery life typically lasts 5 to 7 years under normal conditions. Proper installation ensures optimal performance, and the device is designed to provide reliable operation without requiring frequent replacements. Battery safety is crucial; avoid recharging, disassembling, or exposing it to extreme heat. Replace batteries promptly when depleted to maintain system functionality and safety.

Warranty and Support

The Honeywell 5816 is covered under Honeywell’s warranty, with details available on their official website. Support assistance is accessible through Honeywell’s customer service channels for any inquiries.

Understanding the Honeywell Warranty for the 5816

The Honeywell 5816 is backed by a comprehensive warranty program, ensuring protection against defects in materials and workmanship. The warranty period and terms are outlined on Honeywell’s official website. For detailed information, users can visit Honeywell’s warranty page. Proper installation and maintenance are essential to uphold warranty validity. Customers can contact Honeywell support directly for assistance or clarification on warranty-related matters, as specified in the product manual.

Contacting Honeywell Support for Assistance

To reach Honeywell support, visit their official website at Honeywell’s support page for contact details. Users can access phone numbers, email addresses, and live chat options for technical assistance. For warranty inquiries or troubleshooting, refer to the provided resources or contact their customer service team directly. Regular maintenance and annual inspections are recommended to ensure optimal performance and warranty compliance, as outlined in the product manual.

The Honeywell 5816 is a reliable wireless door/window transmitter offering a 200-foot range and easy installation, making it an excellent choice for home and business security systems.

Final Thoughts on the Honeywell 5816

The Honeywell 5816 is a reliable and versatile wireless door/window transmitter, offering a 200-foot range and easy installation. Its two unique zones provide flexibility for wired or reed switch setups, making it ideal for both indoor and outdoor security applications. With long battery life and robust signal strength, it ensures consistent performance. Perfect for home or business security systems, the Honeywell 5816 delivers dependable protection and peace of mind.

Best Practices for Using the Honeywell 5816

For optimal performance, ensure proper alignment of the magnet with the reed switch and conduct regular signal strength tests. Annual inspections and battery replacements are crucial for reliability. Mount the device securely, following UL guidelines for contact placement. Keep the transmitter clean and avoid extreme temperatures. Refer to the manual for specific setup and troubleshooting steps to maintain functionality and extend the device’s lifespan effectively.

Recommended Posts